Charles Explorer logo
🇬🇧

The use of a hanging mercury drop electrode modified with octane-1-thiol in voltammetric analysis of genotoxic environmental pollutants

Publication at Faculty of Science |
2011

Abstract

Voltammetric behavior of some genotoxic nitro derivatives of aromatic hydrocarbons (nitrobenzene, 1-nitronaphthalene, 2-nitrofluorene, and 9-nitroanthracene) and nitrophenols (2- and 4-nitrophenol) has been studied with the aim to improve the selectivity of their simultaneous voltammetric determination at a hanging mercury drop electrode (HMDE) modified with octane-1-thiol. Optimum conditions were investigated in Britton-Robinson (BR) buffer methanol (1:1) at pH 2.0 - 12.0.

At an unmodified HMDE, only the 4-nitrophenol/1-nitronaphthalene and 4-nitrophenol/2-nitrofluorene pairs could be simultaneously determined in neutral and alkaline media due to the peak potential differences higher than 300 mV. After modification of HMDE with 1.10(-4) and 1.10(-6) mol l(-1) octane-1-thiol, the peak potentials of most analytes (in BR buffer of pH 2.0-methanol 1:1) were shifted to more negative values and their peak heights decreased.

Only in the case of nitromethane, the modification of HMDE with 1.10(-6) mol l(-1) octane-1-thiol led to a positive potential shift and to an increased voltammetric response, caused probably by its accumulation in the octane-1-thiol monolayer. However, the differences in the peak potentials of the analytes at unmodified and modified HMDE were not sufficient for their simultaneous determination.

Further improvement and optimization of the determinations of environmental pollutants are investigated.