Charles Explorer logo
🇬🇧

Technical innovation in minimally invasive repair of pectus excavatum

Publication at Second Faculty of Medicine |
2014

Abstract

The aim of study was to introduce technical innovation of MIRPE which reduces the risk of cardiac injury. Modification of MIRPE method with semiflexible thoracoscope and sternum elevating technique has been used.

Volkmann bone hook has been inserted percutaneously to the sternum. The hook elevates the sternum forward and enlarges the retrosternal space for safer passage of thoracoscopically guided introducer.

Using semiflexible thoracoscope allows better view from various angles via one site of insertion. During the period 2005-2012, the MIRPE was performed on 29 girls and 151 boys; the mean age at the time of surgery was 15.9 years (range 13-18.7 years).

The mean Haller index was 4.7 (range 2.7-20.5). The most common complication was pneumothorax (3.3 %) and the incidence of bar displacement was 2 %.

The most serious complication was cardiac perforation when inserting Lorenz introducer. This occurred in a 16-year-old girl; she required urgent sternotomy with right atrial repair and recovered well.

External elevation of sternum with the hook was used since this case. Subsequent 113 patients underwent surgery without any serious complications.

Technical innovation using semiflexible thoracoscope and hook elevation of the sternum reduces the risk of cardiac injury. The hook opens the anterior mediastinum space effectively and makes the following dissection relatively safe and straightforward.