Off-pump coronary bypass surgery has become a widely used technique during recent years. However, limited data are available with regard to 1-year patency of bypass grafts implanted on the beating heart in unselected consecutive bypass surgery candidates.
The aim of this study was to compare 1-year angiographic patency of bypass grafts done on the beating heart (off pump) with those done classically (on pump). The PRAGUE-4 trial randomized 400 consecutive nonselected cardiac surgery candidates into group A (on pump; n=192) and group B (off pump; n=208).
One-year follow-up coronary angiography was done in 255 patients. The arterial graft patency after 1 year was 91% in both groups.
Saphenous graft patency was 59% (on pump) versus 49% (off pump; P=NS). Saphenous graft patency per patient was lower in the off-pump group: 0.7 patent anastomosis per patient versus 1.1 patent anastomosis in the on-pump group (P<0.01).
There were 46% on-pump patients with all grafts patent versus 52% off-pump patients (P=NS). Grafts anastomosed distally to collateralized chronic total occlusions of native coronary arteries remained patent in 100% on the left anterior descending artery compared with 23% on other arteries (P<0.0001).
The patency of arterial coronary bypass grafts done on the beating heart is excellent and equal to grafts done on pu. The off-pump procedure in the unselected patient population results in fewer patent saphenous grafts per patient.