Imaging knee position using MRI, RSA/CT and 3D digitisation

Publikace na 1. lékařská fakulta |
2005

Tento text není v aktuálním jazyce dostupný. Zobrazuje se verze "en".Abstrakt

The purpose of this study was to compare 3 methods of imaging knee position. Three fresh cadaver knees were imaged at 6 flexion angles between 0degrees and 120degrees by MRI, a combination of RSA and CT and 3D digitisation (in two knees).

Virtual models of all 42 positions were created using suitable computer software. Each virtual model was aligned to a newly defined anatomically based Cartesian coordinate system.

The angular rotations around the 3 coordinate system axes were calculated directly from the aligned virtual models using rigid body kinematics and found to be equally accurate for the 3 methods. The 3 rotations in each knee could be depicted using anatomy-based diagrams for all 3 methods.

We conclude that the 3 methods of data acquisition are equally and adequately accurate in vitro. MRI may be the most useful in vivo.