In situ assessment of the renal microcirculation in mechanically ventilated rats using sidestream dark-field imaging

Publikace na Ústřední knihovna, Lékařská fakulta v Hradci Králové |
2015

Tento text není v aktuálním jazyce dostupný. Zobrazuje se verze "en".Abstrakt

For microcirculation research there is a need for baseline data and feasibility protocols describing microcirculation of various organs. The aim of our study was to examine the reliability and reproducibility of sidestream dark-field (SDF) imaging within the renal cortical microcirculation in rats.

Renal microcirculation was observed using SDF probe placed on the exposed renal surface via the upper midline laparotomy. Video sequences recorded intermittently in short apneic pauses were analyzed off-line by using AVA 3.0 software (MicroVision Medical, Amsterdam, the Netherlands).

Results are expressed as mean (SD) or median (25-75% percentiles). We obtained 60 clear sequences from all recorded analyzable videos from all the animals.

The total small vessel and all vessel density (in mm.mm(-2) ) were (28.79 +- 0.40) and (28.95 +- 0.40), respectively. The perfused small and all vessel density were (28.79 +- 0.40) and (28.95 +- 0.40), respectively.

The DeBacker Score was (19.14 +- 0.43), the proportion of perfused vessels was 100% (100-100%) and the microvascular flow index was 3.49 (3-3.75). We conclude SDF imaging provides a reliable method to examine the renal microvascular bed in vivo and thus can be used for the study of the renal cortical vascular network in various experimental diseases models and clinical settings.