Assessment of left ventricular diastolic function by radionuclide ventriculography in patients with chronic heart failure and reduced ejection fraction

Publikace na Ústřední knihovna, 3. lékařská fakulta |
2014

Tento text není v aktuálním jazyce dostupný. Zobrazuje se verze "en".Abstrakt

Study objective: To compare parameters of diastolic function as assessed by radionuclide ventriculography (RNVG) and Doppler echocardiography (ECHO) in the patients with chronic heart failure and reduced ejection fraction (HF REF). Patients and methods: RNVG and ECHO were performed on the same day in 40 patients with systolic chronic HF, NYHA II and III, with LV EF < 50 % and sinus rhythm, followed at tertiary HF clinic.

Diastolic function was assessed by RNVG using parameters: PFR (peak filling rate [% SV/sec]), TFR - time to peak filling rate (ms), and by ECHO using pulse Doppler parameters: the peak Doppler velocities of early (E) and late diastolic flow (A), the E/A ratio, the calculated mean of the early (E') diastolic velocity of septal and lateral mitral annulus measured by tissue Doppler imaging, and the E/E' ratio. Results: The mean PFR was 421.7 (median 371.0) % SV/sec and TPF was 198.7 ms (median 169.5), the mean E/A ratio was 1.21 (median 0.85) and the E/E' ratio was 9.0 (median 8.40).

TPF correlated significantly (inverse correlation) with the E/A ratio (r = -0.34, p = 0.030), and not significantly with E' (r = -0.27, p = 0.082), the PFR/age ratio correlated with the E/E' ratio (r = -0.31, p = 0.05). Conclusion: Significant correlations of parame-ters of diastolic function as assessed by radionuclide and Doppler studies were identified in the HF REF patients.