The present study aimed to evaluate the effects of ischemic intra-conditioning applied during rest intervals on 30 m sprint performance. Thirty-four trained male (n = 12) and female (n = 22) track and field and rugby athletes volunteered to participate in the study (age = 19.6 +/- 4 years; training experience = 5.3 +/- 1.9 years).
In a randomized and counterbalanced order, participants performed six sets of 30 m sprints under three different testing conditions: without ischemic intra-conditioning, and with ischemic intra-conditioning at 60% or 80% arterial occlusion pressure applied bilaterally before the first trial of the sprint and during the rest periods between all sprint trials. During experimental sessions, subjects perform 6 x 30 m sprints with a 7 min rest interval between attempts.
The cuffs were applied following a 1 min rest period and lasted for 5 min before being released at the 6th minute to allow for reperfusion (1 min + 5 min ischemic intra-conditioning + 1 min reperfusion). The two-way repeated measures ANOVA did not show statistically significant condition x set interaction for time of the sprint (p = 0.06; eta(2) = 0.05).
There was also no main effect of ischemic intra-conditioning for any condition (p = 0.190; eta(2) = 0.05). This study indicates that ischemic intra-conditioning did not enhance the performance of 30 m sprints performed by athletes.
However, ischemic intra-conditioning did not decrease performance either.