Charles Explorer logo
🇨🇿

Arrhythmic Risk In Biventricular Pacing Compared with Left Bundle Branch Area Pacing: Results From The International LBBAP Collaborative Study (I-CLAS)

Publikace na 3. lékařská fakulta |
2024

Tento text není v aktuálním jazyce dostupný. Zobrazuje se verze "en".Abstrakt

Background: Left bundle branch area pacing (LBBAP) may be associated with greater improvement in left ventricular ejection fraction and reduction in death or heart failure hospitalization when compared with biventricular pacing (BVP) in patients requiring cardiac resynchronization therapy (CRT). We sought to compare the occurrence of sustained ventricular tachycardia or ventricular fibrillation (VT/VF) and new onset atrial fibrillation (AF) in patients undergoing BVP and LBBAP.

Methods: This International Collaborative LBBAP Study (I-CLAS) included patients with LVEF3 episodes in 24 hours) was also significantly lower with LBBAP compared with BVP (0.8% vs 2.5%;p=0.013). Among 299 patients with CRT-pacemakers (BVP-111, LBBAP-188), VT/VF occurred in 8 patients in the BVP group vs. none in the LBBAP group (7.2% vs 0%;p30 seconds was significantly lower with LBBAP compared with BVP (2.8% vs 6.6%;HR 0.34;95%CI 0.16-0.73;p=0.008).

The incidence of AF lasting >24 hours was also significantly lower with LBBAP compared with BVP (0.7% vs 2.9%;p=0.015). Conclusions: LBBAP was associated with lower incidence of sustained VT/VF and new-onset AF compared with BVP.

This difference remained significant after adjustment for differences in baseline characteristics between patients with BVP and LBBAP. Physiologic resynchronization by LBBAP may be associated with lower risk of arrhythmias compared with BVP.